Direct Use on Lives |
Apply to and Removal from Hazardous
Live Uninsulated Conductors Permitted |
|
Fast Audible Continuity |
Quick Open-short Tests on
Switches, Fuses, and Wires |
|
Clamp-on Hz |
Measures Non-Invasive Current Frequency
Via Clamp Jaws; 20Hz to 400Hz |
|
DCA, ACA, DC+ACA |
Each 2 Ranges: 200.0A and 2000A |
|
DCV, DC+ACV |
Each 4 Ranges: DCV 6.000V to
1500V; DC+ACV 6.000V to 1000V |
|
UL Listed CAT IV 1kV |
Utility Applications for CAT IV Areas |
|
Dual UL Listed CAT III 1500Vdc |
For Photovoltaics, Battery Banks, Metros,
and Other DC Systems Applications |
|
AC-Coupled ACV |
4 Ranges: 6.000V to 1000V |
|
AC Line-Level Hz |
Measures Noisy High Voltage Frequency
via Test leads; 10Hz to 1999Hz |
|
VFD-ACV + VFD-Hz |
VFD-ACV 4 Ranges: 6.000V to
1000V; VFD-Hz 10 to 400Hz |
|
PC-Comm Interface Capability |
Optional Purchase USB
Cable & PC Software Set |
|
VFD
(Low Pass Filter) |
Measures Fundamental V and Hz
of Most Variable-Frequency-Drives |
|
EMC EN61326-1 Compliance |
Superior Immunity to Interferences with
Reliable Operations and Readings |
|
Fast Auto-Ranging |
Shortens the Time to Measure
and Increases the Ease of Use |
|
Back-Lighted LCD |
Easy Display Viewing in the Dark |
|
Manual-ranging Override |
Auto-ranging with User Selectable
Manual-ranging Override |
|
Rugged & Durable |
High-impact Fire-retarded Housing
with Battery Access Door |
|
Large 55mm DC/AC Jaws |
Measure both DC and AC Non-invasive
Currents up to 2000A |
|
Wide-Range Resistance |
6 Full Ranges 600.0Ω To 40.00MΩ |
|
Relative Zero Mode |
Convenient Readings
Comparison & Offset |
|
AC, AC+DC True RMS |
Ideal for Non-sinusoidal & Complex
Waveforms of Voltages and Currents |
|
Diode Test |
Quick Checks on Diodes and Rectifiers |
|
Wide-Range Capacitance |
6 Full Ranges 60.00nf to 2000µF;
Measures Start & Run Motor Capacitors |
|
Data HOLD |
Freezes the Displaying
Reading for Later View |
|
Type-K Temperature |
Selectable °C or °F Readings;
Comes with a Bkp60 Bead Probe |
|
5ms Crest-MAX |
Fast Capture of In-Rush Current
or Voltage Spikes; Automatic
APO Disable Feature |
|
Ergonomic & Streamlined Body |
Fits Nicely with Single-Handed
Rotary Switch Operation |
|
Auto Power Off |
Intelligently Turns Off Automatically
to Extend Battery Life |
|
Convenient Dual Display |
ACA+Hz or ACV+Hz Readings;
6000 Counts + 2000 Counts |
|
Transient Protection |
12kV 1.2/50µS Lightning or Switching
Surge Protection for Serious Users |
|
EF-Detection |
Both Non-Contact (NCV) & Single-Probe
Voltage Detection for Identifying Live Lines |
|
1500Vdc Input Protection |
Superb Protection for Misinput
on All Functions and Ranges |
|
|
Specifications subject to change without notice.
Patented & patents pending. |
|
TOP |
|