FUNCTION SELECTION |
Toggle Conveniently Between Primary & Secondary Functions |
 |
SMOOTH MODE |
Smooth Out Unstable Insulation Resistance Readings |
 |
AUTO & MANUAL-RANGING |
Auto-ranging With Manual-ranging Override |
 |
ANALOG BAR-GRAPH |
Fast Update Rate 60/sec |
 |
6,000 COUNTS WIDE-VIEW LCD DISPLAY |
5/sec Fast Nominal Update Rate |
 |
DUAL DIGITAL DISPLAY |
Simultaneously View Relevant Parameters In Complementary Display |
 |
ASIC TECHNOLOGY |
Allows More Functions & Features At Affordable Prices |
 |
HIGH ACCURACY |
0.2% Basic DCV Accuracy |
 |
ERGONOMIC STREAMLINE DESIGN |
Fits Comfortably In One's Hand |
 |
LOCK FEATURE |
For Two Handed Continuous Testing Without The Need To Press The TEST Button |
 |
DATA HOLD |
Freezes The Displaying Reading For Later View |
 |
MAX MIN AVG RECORD |
Record Max, Min & Avg Readings; Auto-ranging |
 |
mA & Hz |
Measures Currents & Frequencies In Dual Display |
 |
EARTH CONTINUITY TEST |
Test Currents: ≥200mA @ 2.000Ω Range And ≥90mA @ 20.00Ω Range |
 |
INSULATION RESISTANCE TEST |
5 Test Voltages: 50V, 100V, 250V, 500V & 1000V. It is Useful For Determining The State Of Insulation Material. |
 |
TYPE-K TEMPERATURE |
Measurements -50.0°C To 537.0°C, Selectable °C & °F Readings |
 |
X-SPEED CAPACITANCE |
X-speed Measures Up To 30mF In Only A Few Seconds; 1kV Protection |
 |
RESISTANCE FUNCTION |
Autoranging 600.0Ω To 60.00MΩ |
 |
TRANSIENT PROTECTION |
Up To 8kV 1.2/50μs Lightning Surge; Superb Protection For Serious Users |
 |
LVD SAFETY |
Meets EN61557-1/-2/-4, & EN61010-1/-2-030/-2-033 CAT III 1kV & CAT IV 600V |
 |
EMC |
Meets EN61326-1: 2006(EN55022, EN61000-3-2/-3 & EN61000-4-2/-3/-4/-5/-6/-8/-11) |
 |
PROTECTIVE HOLSTER |
With Holders For Probe Storage And "third Hand" Feature, Replaceable & Washable |
 |
AC TRUE Rms |
For Non-sinusoidal Waveforms Of Complex Voltage Or Current Signals |
 |
INTELLIGENT AUTO-POWER-OFF |
To Extend Battery Life; Awake Resets On Significant Operation & Measurements |
 |
BEEP-JACK™ AUDIBLE & VISIBLE WARNING |
Guards Against Improper "-INS. mA" Terminal Plug In. Decreases Risks Of Damage |
 |
ACCEPTS REMOTE PROBE |
Convenient Activation For Insulation & Earth Continuity Tests. Full Silicone Leads To Minimize Insulation Test Error |
 |
VFD V & Hz FEATURE |
Measures Fundamental Voltage & Frequency Of Most Variable Frequency Drives In Dual Display |
 |
Hz Of LINE LEVEL VOLTAGE |
Measures Noisy High Voltage ACV Frequencies In Dual Display |
 |
HIGH IMPEDANCE VOLTAGES |
1000VAC/DC Measuring Capabilities; High Input Impedance For Load Sensitive Circuits |
 |
FAST AUDIBLE CONTINUITY |
For Quick Open-short Tests On Switches, Fuses And Wires |
 |
DIODE TEST |
For Checking Diodes And Rectifiers |
 |
60.00mV AC/DC RANGES |
0.01mV High Resolution To Test Small Signal Changes |
 |
LOGIC LEVEL Hz |
Measures Digital Logic Level Frequencies Up To 100kHz |
 |
PAPER-WHITE DISPLAY BACKLIGHT |
For Easy Viewing In The Dark |
 |
|
Specifications subject to change without notice.
Patented & patents pending. |
|
TOP |
|